Refrigeration and A/C components

Slider

Carly

 
logo-carly

CARLYCLEAN - Multi-surface cleaner: Cooling and refrigeration, air conditioning, kitchens

Technical description Cooling and refrigeration, air conditioning:

  • Refrigerating and air conditioning systems’ heat exchangers are environments that are subject to heat transfer.
  • An efficient and harmless cleaning of exchangers is hence a priority in order to preserve their efficiency, increase their service life and maintain a healthy environment for the users.Any dirt, grease, dust, corrosion and even bacterium and other micro-organisms act as isolation barriers and contribute to disturbing the exchangers’efficiency. 
  • The air condenser installed outside is directly exposed to these undesirable soils.Cold rooms, refrigerated warehouses and commercial kitchens.  
  • Cleaning surfaces in contact with food is permitted.In an air conditioning system, all particles (dust, greases, fumes) that are small enough to go through the evaporator filter, accumulate on the fins which are generally wet and make up an ideal environment for bacteria and micro-organism development.

    Further information for Caryclean product (PDF)

CARLYBIO - Refrigerating and air conditioning system decontaminants

Technical description:

  • The air conditioning and refrigerating systems can be contaminated by micro-organisms (bacteria, mould, algae…).
  • The development of these micro-organisms is mainly caused by: Warm water (20°C to 45°C).  Nutriments in sufficient amount (for instance, the iron salts produced by corrosion).
  • The accumulation of organic materials, sediments and other micro-organisms.
  • A large part of these micro-organisms can be dispersed in the system by water coming from a condensation or de-icing system.
  • Thus they can damage piping, heat exchangers and other surfaces by forming bio-films. The Legionella Pneumophilia bacterium is a micro-organism that can cause severe infections to man.
  • The water contaminated by the Legionella presents a risk for health when it is dispersed in the air and inhaled by man. 
  • To fight against air conditioning and refrigerating system contamination, the installations must be regularly cleaned-up with CARLYCLEAN, then disinfected with CARLYBIO.

       Further information for Carlybio product (PDF)

CARLYLOC - Refrigerant leak detectors

Technical description:

The French and European regulations on leak detection checks for refrigerating and air conditioning systems aim at:

  • Limiting the emissions of greenhouse effect refrigerants.
  • Enhancing the protection of the ozone layer.
  • The European regulation 2037/2000 imposes refrigerating and air conditioning installations containing more than 3 kg of refrigerant to undergo an air tightness check on a yearly basis. The check should be performed by a company duly registered: when starting-up, when intervening on the circuit, and at least once a year for installations in operation.

    Further information for Carlyloc product  (PDF)

EVCYAC - Vibration eliminators

Technical description:

  • Reduction of the mechanical vibrations transmitted by the compressor to the discharge, liquid, suction and oil return lines, and indirectly, of the noises they generate, and elimination of stresses linked with piping thermal expansion in refrigerating and air conditioning installations.
  • The vibration eliminators have no effect on the reduction of the noises caused by the gas pulsations in the discharge lines. This is the role of the mufflers SCY.

Further information for EVCYAC product  (PDF)

HCYBF - Replaceable core oil filter shells

Technical description:

  • Oil filtering on the oil return line to the compressor sumps of high capacity refrigerating and air conditioning installations.
  • These filters are essential for the proper functioning of oil level regulators and protect the compressors from contaminants that could damage them (metallic chips, filings, oxides, sludge, etc…)they allow the replacement of the oil filters’ active parts only.
  • These filters are recommended for the oil return lines of screw compressors and of centrifuge compressors.

  Further infromation for HCYBF product (PDF)

TURBOIL-R - Oil separator receivers, welded

Technical description:

  • Separation and recovery of the oil carried by the refrigerant in vapour phase at the outlet of compressors, in refrigerating and air conditioning installations.
  • The TURBOIL-R® oil separator receivers limit the amount of oil within the circuit, thus allowing increasing the heat exchangers’ performances and preventing blocking the pressure relief valves, as well as exceptional wear of compressors by lack of oil.
  • They ensure a regulated oil return to the compressor sumps.
  • The selection of TURBOIL-R® oil separator receivers prevents having to install a separate oil receiver.

  Further information for TURBOIL-R product (PDF)

TURBOIL - Oil separators, welded

Technical description:

  • Separation and recovery of the oil carried by the refrigerant in vapour phase at compressor outlet of refrigerating and air conditioning installations.
  • The TURBOIL® oil separators limit the amount of oil within the circuit, thus allowing increasing the performances of the heat exchangers and preventing blocking the expansion valves, as well as the exceptional wear of compressors by lack of oil.
  • They ensure a regulated oil return to the compressor sumps.

  Further information for TURBOIL product (PDF)

LCYE - Suction line accumulators, with heat exchanger

Technical description:

  • Elimination of risks linked to the return of refrigerant in its liquid phase and to the massive oil intake at compressor suction of refrigerating and air conditioning installations.
     
  • The suction line accumulators LCY and LCYE are particularly recommended for installations that are:
  • Exposed to sudden thermal load variations
  • Whose piping lengths are important
  • Operating with cycle inversions.
  • The LCYE liquid suction line accumulators with heat exchanger are particularly recommended for installations with a low overheating of refrigerant vapours at compressor suction (liquid coolant, low temperature display cabinets, vehicle refrigerating, etc …).

 Further information for LCYE product (PDF)

LCY - Suction line accumulators, without heat exchanger

Technical description:

  • Elimination of risks linked to the return of refrigerant in its liquid phase and to the massive oil intake at compressor suction of refrigerating and air conditioning installations.

The suction line accumulators LCY and LCYE are particularly recommended for installations that are:

  • Exposed to sudden thermal load variations
  • Whose piping lengths are important
  • Operating with cycle inversions
  • The LCYE liquid suction line accumulators with heat exchanger are particularly recommended for installations with a low overheating of refrigerant vapours at compressor suction (liquid coolant, low temperature display cabinets, vehicle refrigerating, etc …)

  Further information for LCY products (PDF)

VCYLS - Liquid sight glasses

Technical description:

  • Immediate and direct monitoring of flow, condition or moisture content of the refrigerant in its liquid or diphasic phase in refrigerating and air conditioning installations.

 Further information for VCYLS products (PDF)

VCYL - Liquid sight glasses

Technical description:

  • Immediate and direct monitoring of flow, condition or moisture content of the refrigerant in its liquid or diphasic phase in refrigerating and air conditioning installations.

 Further information for VCYL product (PDF)                                                

CCY HP - Drying cores

Technical description:

  • Interchangeable elements for the filter shells (BDCY, BCY, BCYHP, BBCY, ACY, BACY and HCYBF) ensuring the filtration, drying, or cleaning of the refrigerants and refrigerating oils of the air conditioning and refrigeration installations.

 Further information for CCY-HP product (PDF)

SCY - Discharge line mufflers

Technical description:

  • Reduction of noise caused by gas pulses in the discharge lines of the compressors of refrigerating and air conditioning installations.
  • The mufflers have no effect on the mechanical vibrations transmitted to the pipes by the compressors; this is the role of the vibration eliminators EVCYAC or EVCYDEAC.

 Further information for SCY product (PDF)

FNCY - Cleaning filter driers (suction line)

Technical description:

  • Reinforced refrigerant circuits cleaning and decontamination in refrigerating and air conditioning installations.

Temporary use for:

  • New installations during start-up period for a very efficient protection of compressors against all types of dirt.
  • Existing installations for an efficient refrigerant cleaning after compressor burnout.

  Further information for FNCY product (PDF)

RCY - Filter drier receiver units

Technical description:

  • Refrigerant filtering and drying, and acid neutralization for refrigerating and air conditioning installation liquid lines.
  • The filter driers receivers provide a permanent reserve of dehydrated and filtered refrigerant, for a better supply of the expansion valve, whatever the operating conditions.
  • The filter drier receivers are particularly suited to low capacity installations that operate with a thermostatic pressure relief valve and that are equipped with an air-cooled condenser or a plate condenser.
  • Filter drier receivers fit perfectly within the heat pump systems.

 Further information for RCY product (PDF)

DCY - Anti-acid filter driers

Technical description:

  • Filtering and drying of refrigerants and acid neutralization for liquid lines of refrigerating and air conditioning installations.

 Further information for DCY product (PDF)